{"id":1715,"date":"2019-06-05T07:13:21","date_gmt":"2019-06-05T07:13:21","guid":{"rendered":"http:\/\/www.seac.es\/es\/?page_id=1715"},"modified":"2022-07-15T11:00:50","modified_gmt":"2022-07-15T11:00:50","slug":"argus","status":"publish","type":"page","link":"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/","title":{"rendered":"Argus"},"content":{"rendered":"<div id=\"pl-1715\"  class=\"panel-layout\" ><div id=\"pg-1715-0\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-1715-0\" data-stretch-type=\"full\" ><div id=\"pgc-1715-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1715-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div class=\"panel-widget-style panel-widget-style-for-1715-0-0-0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h1>\u00a0<\/h1>\n<h1>Argus<\/h1>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><div id=\"pg-1715-1\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-1715-1\" data-stretch-type=\"full\" ><div id=\"pgc-1715-1-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1715-1-0-0\" class=\"so-panel widget widget_sow-image panel-first-child panel-last-child\" data-index=\"1\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-image so-widget-sow-image-default-2ec334f0a340-1715\"\n\t\t\t\n\t\t>\n\n<div class=\"sow-image-container\">\n\t\t<img src=\"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2019\/06\/IMG_4642.jpg\" width=\"3999\" height=\"1944\" srcset=\"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2019\/06\/IMG_4642.jpg 3999w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2019\/06\/IMG_4642-300x146.jpg 300w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2019\/06\/IMG_4642-768x373.jpg 768w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2019\/06\/IMG_4642-1024x498.jpg 1024w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2019\/06\/IMG_4642-24x12.jpg 24w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2019\/06\/IMG_4642-36x18.jpg 36w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2019\/06\/IMG_4642-48x23.jpg 48w\" sizes=\"(max-width: 3999px) 100vw, 3999px\" alt=\"\" loading=\"lazy\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><div id=\"pgc-1715-1-1\"  class=\"panel-grid-cell\" ><div id=\"panel-1715-1-1-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"2\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h3>Presentaci\u00f3n<\/h3>\n<p>Se trata de un sistema completo para la monitorizaci\u00f3n continua de la radiaci\u00f3n gamma con una r\u00e1pida capacidad de respuesta en la detecci\u00f3n e identificaci\u00f3n de actividades, incluso de niveles muy bajos de radiaci\u00f3n artificial en el medio ambiente. Es una soluci\u00f3n v\u00e1lida para aplicaciones de monitoreo de radiaci\u00f3n gamma ambiental en el aire y en agua.<\/p>\n<h3>Vers\u00e1til<\/h3>\n<p>V\u00e1lida para m\u00faltiples aplicaciones, tanto para estaciones fijas como m\u00f3viles, gracias a su dise\u00f1o modular.<\/p>\n<h3>F\u00e1cil instalaci\u00f3n<\/h3>\n<p>F\u00e1cil instalaci\u00f3n y muy bajo mantenimiento. Concebida para su funcionamiento en cualquier tipo de ambiente, incluso en las condiciones clim\u00e1ticas m\u00e1s adversas. Fabricada con carcasa herm\u00e9ticamente sellada, IP65.<\/p>\n<h3>Autonom\u00eda<\/h3>\n<p>Gran autonom\u00eda gracias su consumo reducido, llegando a ser ilimitada con el uso de panel solar y bater\u00eda.<\/p>\n<h3>Comunicaci\u00f3n<\/h3>\n<p>Para acceder a la informaci\u00f3n almacenada, la estaci\u00f3n dispone de interfaz de comunicaci\u00f3n LAN\/Ethernet, modem GPRS\/3G y Wifi., modem DSL, RS232, radio o sat\u00e9lite. <br \/>Mediante dichos canales de comunicaci\u00f3n, podemos acceder a la informaci\u00f3n sobre la configuraci\u00f3n de la estaci\u00f3n, a los datos almacenados en memoria interna, realizar operaciones de mantenimiento y estado de la estaci\u00f3n, etc.<\/p>\n<h3>Almacenamiento<\/h3>\n<p>Memoria interna con capacidad para m\u00e1s de 5 meses de datos de espectro en modo de 10 minutos y 5 a\u00f1os de tasa de dosis.<br \/>Tiempos (dos) de muestreo configurables, desde 1 min hasta 24h.<\/p>\n<h3>Opciones<\/h3>\n<p>La estaci\u00f3n est\u00e1 disponible con varios tipos de detector seg\u00fan las necesidades: NaI(TI), o LaBr3(Ce) en diversos tama\u00f1os de detector. Adicionalmente incorpora tubo GM para tasas de dosis hasta 10Sv\/h.<\/p>\n<h3>Accesorios<\/h3>\n<p>La estaci\u00f3n es ampliable con: sensores de lluvia, viento, temperatura, etc.<\/p><\/div>\n<\/div><\/div><div id=\"panel-1715-1-1-1\" class=\"so-panel widget widget_sow-button panel-last-child\" data-index=\"3\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-button so-widget-sow-button-wire-30b3367ab913-1715\"\n\t\t\t\n\t\t><div class=\"ow-button-base ow-button-align-left\">\n\t<a href=\"\/docs-pdf\/GE_IE_CAT_0021.pdf\" class=\"ow-icon-placement-left ow-button-hover\" \t\t>\n\t\t<span>\n\t\t\t\n\t\t\tVer cat\u00e1logo\t\t<\/span>\n\t<\/a>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div id=\"pg-1715-2\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-1715-2\" data-stretch-type=\"full\" ><div id=\"pgc-1715-2-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1715-2-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"4\" ><div class=\"panel-widget-style panel-widget-style-for-1715-2-0-0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h1>\u00a0<\/h1>\n<h1>Argus Caracter\u00edsticas t\u00e9cnicas<\/h1>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><div id=\"pg-1715-3\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-1715-3\" data-stretch-type=\"full\" ><div id=\"pgc-1715-3-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1715-3-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"5\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p><strong>Descripci\u00f3n<\/strong><\/p>\n<hr \/>\n<table width=\"513\">\n<tbody>\n<tr>\n<td width=\"513\">\n<p>Estaci\u00f3n fija o m\u00f3vil<\/p>\n<p>R\u00e1pida capacidad de respuesta<\/p>\n<p>Vers\u00e1til<\/p>\n<p>Dise\u00f1o modular<\/p>\n<p>F\u00e1cil instalaci\u00f3n<\/p>\n<p>Bajo mantenimiento<\/p>\n<p>Gran autonom\u00eda<\/p>\n<p>Comunicaci\u00f3n LAN\/Ethernet.<\/p>\n<p>Medici\u00f3n de tasa de dosis gamma (\u00b5Sv\/h) y actividad (Bq\/m\u00b2)<\/p>\n<p>Identificaci\u00f3n autom\u00e1tica de is\u00f3topos (configurable)<\/p>\n<p>Tubo Geiger-M\u00fcller (GM) alta dosis<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Rango<\/strong><\/p>\n<hr \/>\n<table width=\"513\">\n<tbody>\n<tr>\n<td width=\"279\">\n<p>Rango de medida<\/p>\n<\/td>\n<td width=\"234\">\n<p>10nSv\/h hasta 100\u00b5Sv\/h<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"279\">\n<p>Rango de energ\u00eda<\/p>\n<p>Tiempos de muestreo<\/p>\n<p>Precisi\u00f3n<\/p>\n<\/td>\n<td width=\"234\">\n<p>30 KeV hasta 3 MeV<\/p>\n<p>1min a 24h (Configurables)<\/p>\n<p>10%<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Detectores<\/strong><\/p>\n<hr \/>\n<table width=\"520\">\n<tbody>\n<tr>\n<td width=\"279\">\n<p>NaI(TI)<\/p>\n<\/td>\n<td width=\"241\">\n<p>3\"x3\" o 2\"x2\"<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"279\">\n<p>LaBr3(Ce)<\/p>\n<p>Adicionalmente<\/p>\n<p>Resoluci\u00f3n (Cs137)<\/p>\n<\/td>\n<td width=\"241\">\n<p>1.5\"x1.5\" o 1\"x1\"<\/p>\n<p>Tubo Geiger-M\u00fcller (GM)<\/p>\n<p>7% NaI(TI)<\/p>\n<p>3.5% LaBr3(Ce)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"279\">\n<p>MCA<\/p>\n<\/td>\n<td width=\"241\">\n<p>eMorpho (BridgePort Instruments)<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Opciones<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"279\">\n<p>Sensores<\/p>\n<\/td>\n<td width=\"241\">\n<p>Temperatura, humedad, Lluvia, viento, estaci\u00f3n meteorol\u00f3gica completa, etc.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"279\">\n<p>Soporte<\/p>\n<\/td>\n<td width=\"241\">\n<p>Soporte t\u00e1ctico con panel solar<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div><\/div><div id=\"panel-1715-3-0-1\" class=\"so-panel widget widget_sow-image panel-last-child\" data-index=\"6\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-image so-widget-sow-image-default-2ec334f0a340-1715\"\n\t\t\t\n\t\t>\n\n<div class=\"sow-image-container\">\n\t\t<img src=\"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1.png\" width=\"1026\" height=\"875\" srcset=\"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1.png 1026w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1-300x256.png 300w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1-768x655.png 768w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1-1024x873.png 1024w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1-24x20.png 24w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1-36x31.png 36w, https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1-48x41.png 48w\" sizes=\"(max-width: 1026px) 100vw, 1026px\" title=\"arg\" alt=\"\" loading=\"lazy\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><div id=\"pgc-1715-3-1\"  class=\"panel-grid-cell panel-grid-cell-empty\" ><\/div><div id=\"pgc-1715-3-2\"  class=\"panel-grid-cell\" ><div id=\"panel-1715-3-2-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"7\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p><strong>Comunicaciones<\/strong><\/p>\n<hr \/>\n<table width=\"533\">\n<tbody>\n<tr>\n<td width=\"533\">\n<p>LAN\/Ethernet<\/p>\n<p>LAN\/Wifi<\/p>\n<p>GPRS\/3G<\/p>\n<p>RS232\/RS485<\/p>\n<p>Radio (Opcional)<\/p>\n<p>Sat\u00e9lite (Opcional)<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Canales<\/strong><\/p>\n<hr \/>\n<table width=\"536\">\n<tbody>\n<tr>\n<td width=\"264\">\n<p>N\u00famero de canales<\/p>\n<\/td>\n<td width=\"272\">\n<p>Hasta 4096<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Almacenamiento<\/strong><\/p>\n<hr \/>\n<table width=\"548\">\n<tbody>\n<tr>\n<td width=\"260\">\n<p>Memoria interna<\/p>\n<\/td>\n<td width=\"288\">\n<p>Seg\u00fan configuraci\u00f3n hasta<\/p>\n<p>5 meses espectro (10 min)<\/p>\n<p>5 a\u00f1os tasa de dosis (10 minutos)<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Alimentaci\u00f3n<\/strong><\/p>\n<hr \/>\n<table width=\"547\">\n<tbody>\n<tr>\n<td width=\"260\">\n<p>Tensi\u00f3n de alimentaci\u00f3n<\/p>\n<p>Consumo<\/p>\n<p>Bater\u00eda de respaldo<\/p>\n<p>Opcionalmente<\/p>\n<p>Rango de temperatura<\/p>\n<\/td>\n<td width=\"288\">\n<p>12VDC (nominal)<\/p>\n<p>2.1W<\/p>\n<p>5-20 d\u00edas<\/p>\n<p>Panel solar<\/p>\n<p>-40\u00baC a +60\u00baC<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Mec\u00e1nica y dimensiones<\/strong><\/p>\n<hr \/>\n<table width=\"553\">\n<tbody>\n<tr>\n<td width=\"262\">\n<p>Carcasa<\/p>\n<p>Di\u00e1metro<\/p>\n<p>Altura<\/p>\n<p>Peso<\/p>\n<\/td>\n<td width=\"291\">\n<p>Herm\u00e9tica sellada (IP65)<\/p>\n<p>105mm<\/p>\n<p>520mm<\/p>\n<p>2.5Kg<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div><\/div><div id=\"panel-1715-3-2-1\" class=\"so-panel widget widget_sow-button panel-last-child\" data-index=\"8\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-button so-widget-sow-button-wire-30b3367ab913-1715\"\n\t\t\t\n\t\t><div class=\"ow-button-base ow-button-align-left\">\n\t<a href=\"\/docs-pdf\/GE_IE_CAT_0021.pdf\" class=\"ow-icon-placement-left ow-button-hover\" \t\t>\n\t\t<span>\n\t\t\t\n\t\t\tVer cat\u00e1logo\t\t<\/span>\n\t<\/a>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>\u00a0 Argus Presentaci\u00f3n Se trata de un sistema completo para la monitorizaci\u00f3n continua de la radiaci\u00f3n gamma con una r\u00e1pida capacidad de respuesta en la<\/p>\n","protected":false},"author":1,"featured_media":1710,"parent":664,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Argus - SEAC<\/title>\n<meta name=\"description\" content=\"Sistema completo para la monitorizaci\u00f3n continua de la radiaci\u00f3n gamma con una r\u00e1pida capacidad de respuesta en la detecci\u00f3n e identificaci\u00f3n de actividades.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Argus - SEAC\" \/>\n<meta property=\"og:description\" content=\"Sistema completo para la monitorizaci\u00f3n continua de la radiaci\u00f3n gamma con una r\u00e1pida capacidad de respuesta en la detecci\u00f3n e identificaci\u00f3n de actividades.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/\" \/>\n<meta property=\"og:site_name\" content=\"SEAC\" \/>\n<meta property=\"article:modified_time\" content=\"2022-07-15T11:00:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1026\" \/>\n\t<meta property=\"og:image:height\" content=\"875\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"adminblogseac\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.seac.es\/es\/#organization\",\"name\":\"SEAC S.A.\",\"url\":\"https:\/\/www.seac.es\/es\/\",\"sameAs\":[],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.seac.es\/es\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2017\/08\/logoSEAC240x105.png\",\"contentUrl\":\"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2017\/08\/logoSEAC240x105.png\",\"width\":240,\"height\":105,\"caption\":\"SEAC S.A.\"},\"image\":{\"@id\":\"https:\/\/www.seac.es\/es\/#\/schema\/logo\/image\/\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.seac.es\/es\/#website\",\"url\":\"https:\/\/www.seac.es\/es\/\",\"name\":\"SEAC\",\"description\":\"Meteorolog\u00eda y equipos de medida\",\"publisher\":{\"@id\":\"https:\/\/www.seac.es\/es\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.seac.es\/es\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/#primaryimage\",\"url\":\"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1.png\",\"contentUrl\":\"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1.png\",\"width\":1026,\"height\":875},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/#webpage\",\"url\":\"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/\",\"name\":\"Argus - SEAC\",\"isPartOf\":{\"@id\":\"https:\/\/www.seac.es\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/#primaryimage\"},\"datePublished\":\"2019-06-05T07:13:21+00:00\",\"dateModified\":\"2022-07-15T11:00:50+00:00\",\"description\":\"Sistema completo para la monitorizaci\u00f3n continua de la radiaci\u00f3n gamma con una r\u00e1pida capacidad de respuesta en la detecci\u00f3n e identificaci\u00f3n de actividades.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/www.seac.es\/es\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Productos\",\"item\":\"https:\/\/www.seac.es\/es\/productos\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Sensores\",\"item\":\"https:\/\/www.seac.es\/es\/productos\/sensores\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Argus\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Argus - SEAC","description":"Sistema completo para la monitorizaci\u00f3n continua de la radiaci\u00f3n gamma con una r\u00e1pida capacidad de respuesta en la detecci\u00f3n e identificaci\u00f3n de actividades.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/","og_locale":"es_ES","og_type":"article","og_title":"Argus - SEAC","og_description":"Sistema completo para la monitorizaci\u00f3n continua de la radiaci\u00f3n gamma con una r\u00e1pida capacidad de respuesta en la detecci\u00f3n e identificaci\u00f3n de actividades.","og_url":"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/","og_site_name":"SEAC","article_modified_time":"2022-07-15T11:00:50+00:00","og_image":[{"width":1026,"height":875,"url":"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1.png","type":"image\/png"}],"author":"adminblogseac","twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/www.seac.es\/es\/#organization","name":"SEAC S.A.","url":"https:\/\/www.seac.es\/es\/","sameAs":[],"logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.seac.es\/es\/#\/schema\/logo\/image\/","url":"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2017\/08\/logoSEAC240x105.png","contentUrl":"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2017\/08\/logoSEAC240x105.png","width":240,"height":105,"caption":"SEAC S.A."},"image":{"@id":"https:\/\/www.seac.es\/es\/#\/schema\/logo\/image\/"}},{"@type":"WebSite","@id":"https:\/\/www.seac.es\/es\/#website","url":"https:\/\/www.seac.es\/es\/","name":"SEAC","description":"Meteorolog\u00eda y equipos de medida","publisher":{"@id":"https:\/\/www.seac.es\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.seac.es\/es\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"es"},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/#primaryimage","url":"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1.png","contentUrl":"https:\/\/www.seac.es\/es\/wp-content\/uploads\/2018\/04\/arg-1.png","width":1026,"height":875},{"@type":"WebPage","@id":"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/#webpage","url":"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/","name":"Argus - SEAC","isPartOf":{"@id":"https:\/\/www.seac.es\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/#primaryimage"},"datePublished":"2019-06-05T07:13:21+00:00","dateModified":"2022-07-15T11:00:50+00:00","description":"Sistema completo para la monitorizaci\u00f3n continua de la radiaci\u00f3n gamma con una r\u00e1pida capacidad de respuesta en la detecci\u00f3n e identificaci\u00f3n de actividades.","breadcrumb":{"@id":"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.seac.es\/es\/productos\/sensores\/argus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.seac.es\/es\/"},{"@type":"ListItem","position":2,"name":"Productos","item":"https:\/\/www.seac.es\/es\/productos\/"},{"@type":"ListItem","position":3,"name":"Sensores","item":"https:\/\/www.seac.es\/es\/productos\/sensores\/"},{"@type":"ListItem","position":4,"name":"Argus"}]}]}},"_links":{"self":[{"href":"https:\/\/www.seac.es\/es\/wp-json\/wp\/v2\/pages\/1715"}],"collection":[{"href":"https:\/\/www.seac.es\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.seac.es\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.seac.es\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.seac.es\/es\/wp-json\/wp\/v2\/comments?post=1715"}],"version-history":[{"count":42,"href":"https:\/\/www.seac.es\/es\/wp-json\/wp\/v2\/pages\/1715\/revisions"}],"predecessor-version":[{"id":3185,"href":"https:\/\/www.seac.es\/es\/wp-json\/wp\/v2\/pages\/1715\/revisions\/3185"}],"up":[{"embeddable":true,"href":"https:\/\/www.seac.es\/es\/wp-json\/wp\/v2\/pages\/664"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.seac.es\/es\/wp-json\/wp\/v2\/media\/1710"}],"wp:attachment":[{"href":"https:\/\/www.seac.es\/es\/wp-json\/wp\/v2\/media?parent=1715"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}