{"id":1114,"date":"2017-10-04T11:06:09","date_gmt":"2017-10-04T11:06:09","guid":{"rendered":"http:\/\/www.seac.es\/es\/?page_id=1114"},"modified":"2022-04-28T07:38:04","modified_gmt":"2022-04-28T07:38:04","slug":"esc32","status":"publish","type":"page","link":"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/","title":{"rendered":"ESC32"},"content":{"rendered":"<div id=\"pl-1114\"  class=\"panel-layout\" ><div id=\"pg-1114-0\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-1114-0\" data-stretch-type=\"full\" ><div id=\"pgc-1114-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1114-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div class=\"panel-widget-style panel-widget-style-for-1114-0-0-0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h1>\u00a0<\/h1>\n<h1>ESC32 Datalogger \/ Data interface<\/h1>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><div id=\"pg-1114-1\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-1114-1\" data-stretch-type=\"full\" ><div id=\"pgc-1114-1-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1114-1-0-0\" class=\"so-panel widget widget_sow-image panel-first-child panel-last-child\" data-index=\"1\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-image so-widget-sow-image-default-2ec334f0a340-1114\"\n\t\t\t\n\t\t>\n\n<div class=\"sow-image-container\">\n\t\t<img src=\"https:\/\/www.seac.es\/en\/wp-content\/uploads\/2022\/04\/esc32_640_transp.png\" width=\"956\" height=\"640\" srcset=\"https:\/\/www.seac.es\/en\/wp-content\/uploads\/2022\/04\/esc32_640_transp.png 956w, https:\/\/www.seac.es\/en\/wp-content\/uploads\/2022\/04\/esc32_640_transp-300x201.png 300w, https:\/\/www.seac.es\/en\/wp-content\/uploads\/2022\/04\/esc32_640_transp-768x514.png 768w, https:\/\/www.seac.es\/en\/wp-content\/uploads\/2022\/04\/esc32_640_transp-24x16.png 24w, https:\/\/www.seac.es\/en\/wp-content\/uploads\/2022\/04\/esc32_640_transp-36x24.png 36w, https:\/\/www.seac.es\/en\/wp-content\/uploads\/2022\/04\/esc32_640_transp-48x32.png 48w, https:\/\/www.seac.es\/en\/wp-content\/uploads\/2022\/04\/esc32_640_transp-272x182.png 272w\" sizes=\"(max-width: 956px) 100vw, 956px\" alt=\"\" loading=\"lazy\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><div id=\"pgc-1114-1-1\"  class=\"panel-grid-cell\" ><div id=\"panel-1114-1-1-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"2\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h3>Overview<\/h3>\n<p>This data logger has been designed for data acquisition and transmission of meteorological and environmental sensors. Its low power consumption makes it an ideal solution for telemetry applications.<br \/>It is based on our RD32 datalogger, without display and housed in a weatherproof case with IP65, M12 connectors.<\/p>\n<h3>Sensors<\/h3>\n<p>The ESC32 is provided with 8 analog and 14 digital inputs, with scalable and programmable ranges and 2 serial ports (RS232, RS485). They make it suitable for the most part of the sensors on the market, even the intelligent ones.<\/p>\n<h3>Storage<\/h3>\n<p>Storing data internally (512KB RAM) is reliable because the ESC32 is provided with an internal battery with high autonomy.<\/p>\n<h3>Low Power<\/h3>\n<p>The RD32 perfectly fits field installations in limited energy conditions. Energy savings algorithms are included in the software. Electronics and software are specifically low power oriented in order to maximize the autonomy.<\/p>\n<h3>Management<\/h3>\n<p>The ESC32 has one RS485 port to carry out a user-friendly management through a command console.<br \/>From this terminal we can perform: parameters configuration, operation monitoring, alarms management and visualization of stored and real time data.<br \/>Access to information is also available using Modbus protocol, well suited for multiple equipment facilities. <\/p>\n<h3>Time synchronization<\/h3>\n<p>An external GPS connected to an RS232\/485 port carries out Time synchronization.<\/p><\/div>\n<\/div><\/div><div id=\"panel-1114-1-1-1\" class=\"so-panel widget widget_sow-button panel-last-child\" data-index=\"3\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-button so-widget-sow-button-wire-30b3367ab913-1114\"\n\t\t\t\n\t\t><div class=\"ow-button-base ow-button-align-left\">\n\t<a href=\"\/docs-pdf\/GE_IE_CAT_0019.pdf\" class=\"ow-icon-placement-left ow-button-hover\" \t\t>\n\t\t<span>\n\t\t\t\n\t\t\tBrochure\t\t<\/span>\n\t<\/a>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div id=\"pg-1114-2\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-1114-2\" data-stretch-type=\"full\" ><div id=\"pgc-1114-2-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1114-2-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"4\" ><div class=\"panel-widget-style panel-widget-style-for-1114-2-0-0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h1>\u00a0<\/h1>\n<h1>ESC32 Technical features<\/h1>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><div id=\"pg-1114-3\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-1114-3\" data-stretch-type=\"full\" ><div id=\"pgc-1114-3-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1114-3-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"5\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p><strong>Entrada sensores<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"119\">Anal\u00f3gicas<\/td>\n<td width=\"186\">\n<p>Voltage mode 0-1 Vcc; 4-20 mA, etc<br \/>8 Ch. in common mode<br \/>4 Ch. in differencial mode<br \/>2 Ch. In PT100 mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"119\">Digitales<\/td>\n<td width=\"186\">7 channels<\/td>\n<\/tr>\n<tr>\n<td width=\"119\">\u00a0<\/td>\n<td width=\"186\">5 frecuencia\/contador<\/td>\n<\/tr>\n<tr>\n<td width=\"119\">\u00a0<\/td>\n<td width=\"186\">1\u00a0 8 bits parallel or serial synchronous<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Measuring ranges, resolution and accuracy<\/strong><\/p>\n<hr \/>\n<table style=\"height: 360px;\" width=\"315\">\n<tbody>\n<tr>\n<td width=\"119\">\u00a0<\/td>\n<td style=\"text-align: left;\" width=\"60\">\n<p style=\"text-align: center;\">Range<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"60\">Resolution<\/td>\n<td style=\"text-align: left;\" width=\"60\">\n<p style=\"text-align: center;\">Accuracy<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"119\">Analog<\/td>\n<td width=\"60\">\n<p style=\"text-align: center;\">0\u00f72.4 V<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"60\">50 uV<\/td>\n<td width=\"60\">\n<p style=\"text-align: center;\">500 uV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"60\">\n<p style=\"text-align: center;\">0\u00f770 mV<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"60\">10 uV<\/td>\n<td width=\"60\">\n<p style=\"text-align: center;\">100 uV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"119\">Digital\u00a0frequency<\/td>\n<td width=\"60\">\n<p style=\"text-align: center;\">10 KHz<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"60\">1 Hz<\/td>\n<td width=\"60\">\n<p style=\"text-align: center;\">1 Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\" width=\"119\">Pulse counter<\/td>\n<td style=\"text-align: left;\" width=\"60\">\n<p style=\"text-align: center;\">65535<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"60\">1 pulse<\/td>\n<td width=\"60\">\n<p style=\"text-align: center;\">1 pulse<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Storage<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"119\">Internal memory<\/td>\n<td width=\"180\">512 Kbytes (RAM with battery)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Measurements<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"119\"><del>Tipo tiempos<\/del><\/td>\n<td width=\"180\">Capture, sampling, integration<\/td>\n<\/tr>\n<tr>\n<td width=\"119\">Range<\/td>\n<td width=\"180\">1 sec. to 12 hours<\/td>\n<\/tr>\n<tr>\n<td width=\"119\"><del>Escalado<\/del><\/td>\n<td width=\"180\">Ej.: -30\u00baC~70\u00baC, 4-20mA, etc.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Clock<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"119\">Type<\/td>\n<td width=\"180\">dd\/mm\/yyyy - hh:mm:ss<\/td>\n<\/tr>\n<tr>\n<td width=\"119\">Resolution and drift<\/td>\n<td width=\"180\">1 sec. \u2013 10 ppm.<\/td>\n<\/tr>\n<tr>\n<td width=\"119\">Synchronization<\/td>\n<td width=\"180\">GPS or manual<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Serial communication<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"125\">Port<\/td>\n<td width=\"180\">Isolated RS485 \/ RS422(1200 ... 9.600 bps)<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Protocol<\/td>\n<td width=\"180\">ModBus and management console<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"305\">\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Management and control<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"125\">Type<\/td>\n<td width=\"180\">Console<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Configuration<\/td>\n<td width=\"180\">Set of commands for configuration, supervision, alarms management and visualization<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Data<\/td>\n<td width=\"180\">\n<p>Real time data request. Stored RAM and CF data request<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Diagnostic<\/td>\n<td width=\"180\">Diagnostic mode with real time input data Reading<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div><\/div><\/div><div id=\"pgc-1114-3-1\"  class=\"panel-grid-cell panel-grid-cell-empty\" ><\/div><div id=\"pgc-1114-3-2\"  class=\"panel-grid-cell\" ><div id=\"panel-1114-3-2-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"6\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p><strong>Digital outputs<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"125\">Number<\/td>\n<td width=\"180\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Type<\/td>\n<td width=\"180\">Isolated, open collector<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Modes<\/td>\n<td width=\"180\">Alarm, timed control or generic configurable output<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Power supply<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"125\">Internal<\/td>\n<td width=\"180\">3.7 V Litium Ion battery for real time clock and Back-up<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">External<\/td>\n<td width=\"180\">6 to 16VDC<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Management<\/td>\n<td width=\"180\">Internal and external batteries measurement<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Alarm<\/td>\n<td width=\"180\">External digital input for battery charge failure detection<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Operating consumption<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"125\">Active<\/td>\n<td width=\"180\">&lt;15 mA<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Low power<\/td>\n<td width=\"180\">&lt;6 mA<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Sleep<\/td>\n<td width=\"180\">&lt;1 mA<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Serial port<\/td>\n<td width=\"180\">20 mA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Sensors power suply<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"125\">Power<\/td>\n<td width=\"180\">Sensors power supply input independent of equipment power supply<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Range<\/td>\n<td width=\"180\">8 to 24 VDC<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Supply mode<\/td>\n<td width=\"180\">Optoisolated and individual mode for each group of sensors<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Environmental ranges<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"125\">Operation<\/td>\n<td width=\"180\">-30\u00baC to +70\u00baC<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Storage<\/td>\n<td width=\"180\">-30\u00baC to +85\u00baC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Body<\/strong><\/p>\n<hr \/>\n<table>\n<tbody>\n<tr>\n<td width=\"125\">Housing<\/td>\n<td width=\"180\">Polycarbonate IP65 case<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Dimensions ( LxWxH )<\/td>\n<td width=\"180\">200 x 148 x 66 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">Weight<\/td>\n<td width=\"180\">790 Grs<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">\u00a0<\/td>\n<td width=\"180\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td width=\"125\">\u00a0<\/td>\n<td width=\"180\">\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div><\/div><div id=\"panel-1114-3-2-1\" class=\"so-panel widget widget_sow-button panel-last-child\" data-index=\"7\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-button so-widget-sow-button-wire-30b3367ab913-1114\"\n\t\t\t\n\t\t><div class=\"ow-button-base ow-button-align-left\">\n\t<a href=\"\/docs-pdf\/GE_IE_CAT_0019.pdf\" class=\"ow-icon-placement-left ow-button-hover\" \t\t>\n\t\t<span>\n\t\t\t\n\t\t\tBrochure\t\t<\/span>\n\t<\/a>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>\u00a0 ESC32 Datalogger \/ Data interface Overview This data logger has been designed for data acquisition and transmission of meteorological and environmental sensors. Its low<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":280,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ESC32 - SEAC<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ESC32 - SEAC\" \/>\n<meta property=\"og:description\" content=\"\u00a0 ESC32 Datalogger \/ Data interface Overview This data logger has been designed for data acquisition and transmission of meteorological and environmental sensors. Its low\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/\" \/>\n<meta property=\"og:site_name\" content=\"SEAC\" \/>\n<meta property=\"article:modified_time\" content=\"2022-04-28T07:38:04+00:00\" \/>\n<meta name=\"author\" content=\"adminblogseac\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.seac.es\/en\/#organization\",\"name\":\"SEAC S.A.\",\"url\":\"https:\/\/www.seac.es\/en\/\",\"sameAs\":[],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.seac.es\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.seac.es\/en\/wp-content\/uploads\/2017\/08\/logoSEAC240x105.png\",\"contentUrl\":\"https:\/\/www.seac.es\/en\/wp-content\/uploads\/2017\/08\/logoSEAC240x105.png\",\"width\":240,\"height\":105,\"caption\":\"SEAC S.A.\"},\"image\":{\"@id\":\"https:\/\/www.seac.es\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.seac.es\/en\/#website\",\"url\":\"https:\/\/www.seac.es\/en\/\",\"name\":\"SEAC\",\"description\":\"Weather instruments and equipment\",\"publisher\":{\"@id\":\"https:\/\/www.seac.es\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.seac.es\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/#webpage\",\"url\":\"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/\",\"name\":\"ESC32 - SEAC\",\"isPartOf\":{\"@id\":\"https:\/\/www.seac.es\/en\/#website\"},\"datePublished\":\"2017-10-04T11:06:09+00:00\",\"dateModified\":\"2022-04-28T07:38:04+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.seac.es\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.seac.es\/en\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Dataloggers\",\"item\":\"https:\/\/www.seac.es\/en\/products\/dataloggers\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"ESC32\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ESC32 - SEAC","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/","og_locale":"en_US","og_type":"article","og_title":"ESC32 - SEAC","og_description":"\u00a0 ESC32 Datalogger \/ Data interface Overview This data logger has been designed for data acquisition and transmission of meteorological and environmental sensors. Its low","og_url":"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/","og_site_name":"SEAC","article_modified_time":"2022-04-28T07:38:04+00:00","author":"adminblogseac","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/www.seac.es\/en\/#organization","name":"SEAC S.A.","url":"https:\/\/www.seac.es\/en\/","sameAs":[],"logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.seac.es\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.seac.es\/en\/wp-content\/uploads\/2017\/08\/logoSEAC240x105.png","contentUrl":"https:\/\/www.seac.es\/en\/wp-content\/uploads\/2017\/08\/logoSEAC240x105.png","width":240,"height":105,"caption":"SEAC S.A."},"image":{"@id":"https:\/\/www.seac.es\/en\/#\/schema\/logo\/image\/"}},{"@type":"WebSite","@id":"https:\/\/www.seac.es\/en\/#website","url":"https:\/\/www.seac.es\/en\/","name":"SEAC","description":"Weather instruments and equipment","publisher":{"@id":"https:\/\/www.seac.es\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.seac.es\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/#webpage","url":"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/","name":"ESC32 - SEAC","isPartOf":{"@id":"https:\/\/www.seac.es\/en\/#website"},"datePublished":"2017-10-04T11:06:09+00:00","dateModified":"2022-04-28T07:38:04+00:00","breadcrumb":{"@id":"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.seac.es\/en\/products\/dataloggers\/esc32\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.seac.es\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.seac.es\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Dataloggers","item":"https:\/\/www.seac.es\/en\/products\/dataloggers\/"},{"@type":"ListItem","position":4,"name":"ESC32"}]}]}},"_links":{"self":[{"href":"https:\/\/www.seac.es\/en\/wp-json\/wp\/v2\/pages\/1114"}],"collection":[{"href":"https:\/\/www.seac.es\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.seac.es\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.seac.es\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.seac.es\/en\/wp-json\/wp\/v2\/comments?post=1114"}],"version-history":[{"count":47,"href":"https:\/\/www.seac.es\/en\/wp-json\/wp\/v2\/pages\/1114\/revisions"}],"predecessor-version":[{"id":2583,"href":"https:\/\/www.seac.es\/en\/wp-json\/wp\/v2\/pages\/1114\/revisions\/2583"}],"up":[{"embeddable":true,"href":"https:\/\/www.seac.es\/en\/wp-json\/wp\/v2\/pages\/280"}],"wp:attachment":[{"href":"https:\/\/www.seac.es\/en\/wp-json\/wp\/v2\/media?parent=1114"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}